| Sign In | Join Free | My benadorassociates.com |
|
length : 10mm
Number of Ports : 1
Supplementary Features : -
Number of Contacts : 4P
Mounting Type : 侧插
Center Height : -
Current Rating : 1.5A
Detection color : 白色
Voltage Rating : 30V
Operating Temperature : -25℃~+85℃
Connector Type : Type-A
Connect-Disconnect Life : 5千次
Gender : 母
Description : USB-A (USB TYPE-A) Receptacle Connector 4 Position Vertical, Flag
Mfr. Part # : AF 10.0 CC
Package : Through Hole
Model Number : AF 10.0 CC
This specification details the requirements for the USB AF 10.0 CC product from Shenzhen Shouhan Technology Co., Ltd. It covers its electrical, mechanical, and durability characteristics, designed for operation within a specific temperature and atmospheric range. The product is suitable for applications requiring reliable connection and disconnection under various conditions.
| Item | Test Conditions | Performance | Specification |
| RATING | |||
| Rated Value | DC 30V 1.5A | ||
| Operating Temperature Range | -25~85C | ||
| STANDARD ATMOSPHERIC CONDITIONS | |||
| Temperature | Unless otherwise specified | 5C TO 35 | |
| Humidity | Unless otherwise specified | 45% TO 85% | |
| Pressure | Unless otherwise specified | 86Kpa TO 106Kpa | |
| MECHANICAL | |||
| Connection Force | After connecting and disconnecting using standard plug gauge 3 times | 35N MAX | |
| Disconnection Force | After connecting and disconnecting using standard plug gauge 3 times | 8N MIN | |
| Terminal Strength | Static load of 0.1N/m (1kgf/cm) applied to terminal tip for 1 min in any direction | No damage to terminal (cracks, looseness, play); satisfied electrical and mechanical characteristics | |
| ELECTRICAL | |||
| Contact Resistance | Measured at small current (100mA or less), 1000Hz | 30m MAX | |
| Insulation Resistance | Apply 100V DC for 1 min (between body and conductor; between non-contacting conductors; between non-contacting conductors when plug is inserted) | 1000M MIN | |
| Dielectric Strength | Apply AC 500V (rms, 50~60Hz) for 1 min, trip current: 0.5mA (between body and conductor; between non-contacting conductors; between non-contacting conductors when plug is inserted) | No insulation damage, arcing, or breakdown | |
| DURABILITY | |||
| Solderability Test | Terminal top dipped 1mm in solder bath at 2505 for 50.5 seconds | (1) Solder wetting time 3 sec (2) Soldering area > 75% | |
| Resistance to Soldering Heat Test (Reflow Soldering) | Preheat: Copper foil surface reaches 180, 120s after PCB enters equipment. Peak Temp: Copper foil surface reaches 2505 within 5 seconds. | No deformation of case or excessive looseness of terminals; satisfied electrical and mechanical characteristics | |
| (Soldering Iron Method) Bit temp 3305, application time 30.5 sec (no excessive pressure on terminal) | No deformation of case or excessive looseness of terminals; satisfied electrical and mechanical characteristics | ||
| Humidity Test | Stored at 402 and 90%-96% humidity for 96 hours, then maintained at standard atmospheric conditions for 1 hour | ||
| Heat Test | Stored at 702 for 96 hours, then subjected to controlled recovery for 1 hour | No damage on appearance; satisfied mechanical and electrical characteristics | |
| Cold Test | Stored at -253 for 96 hours, then subjected to controlled recovery for 1 hour | No damage on appearance; satisfied mechanical and electrical characteristics | |
| Life Test | Connection/disconnection 5000 cycles at 10-20 cycles/min (rated condition, non-inductive load) | (1) Contact Resistance 0.1 (2) Disconnection Force 0.8 to 2.0N (3) Satisfied mechanical and electrical characteristics | |
| Connection/disconnection 5000 cycles at 10-25 cycles/min (no load) | |||
| Temperature Cycling Test | Subjected to 5 cycles of conditions (shown in figure), then returned to room ambient for 30 minutes. | No deformation or cracks in molded part. Insertion & Extraction Force: 3 to 20N Contact Resistance: MAX.30M Insulation Resistance: MIN.100 M Dielectric Withstanding Voltage: 100VAC/min (between terminals) | |
| Temp(): 70 (0.5hr) -> 0 (1hr) -> -20 (8hr) -> 0 (0.5hr) -> 70 (0.5hr) | |||
| Cold & Heat Shock Test | Subjected to 5 cycles of conditions (shown in figure), then returned to room ambient for 30 minutes. | No deformation or cracks in molded part. Insertion & Extraction Force: 3 to 25N Contact Resistance: MAX.30M Insulation Resistance: MIN.100 M Dielectric Withstanding Voltage: 500VAC/min (between terminals) | |
| Temp(): 70 (1hr) -> 0 (0.5hr) -> -20 (8hr) -> 0 (0.5hr) -> 70 (0.5hr) | |||
|
|
connection SHOU HAN AF 10.0 CC connector engineered for stable electrical and mechanical performance Images |