| Sign In | Join Free | My benadorassociates.com |
|
Number of Contacts : 6P
Operating Temperature : -40℃~+85℃
Connect-Disconnect Life : 3,000 Cycles
Model Number : TYPE-C 6P
Stock : 5280
Description : USB-C (USB TYPE-C) Receptacle Connector 6 Position Surface Mount, Right Angle
Voltage Rating : 5V
Detection color : Black
Gender : Female
Connector Type : Type-C
Delivery Time : 1工作日
Mounting Type : Surface Mount, Right Angle
MOQ : 20
Packaging Details : SMD
Brand Name : TYPE-C 6P
Number of Ports : 1
Current Rating : 3A
Function: TYPE-C 6P connector for data and power transmission.
Usage: Designed for use within a practical temperature range of -30C to 85C under standard atmospheric conditions.
Applications: Suitable for various electronic devices requiring USB Type-C connectivity.
| Item | Test Conditions | Performance | Specification |
|---|---|---|---|
| Connection Force | Measurement shall be made after connecting and disconnecting using standard plug gauge 3 times. | Insertion Force | 5~20 N |
| Measurement shall be made after connecting and disconnecting using standard plug gauge 3 times. | Disconnect Force | 6~20 N | |
| Terminal Strength | A static load of 0.1N/m (1kgf/cm) shall be applied to the tip of the terminal for 1 min in any direction. There shall be no damage to the terminal such as cracks, looseness or play. Electrical and mechanical characteristics shall be satisfied. | Performance | Satisfied |
| Contact Resistance | Measured at small current (100mA or less) 1000Hz. | Performance | 40 m MAX |
| Insulation Resistance | Apply a voltage of 100V DC for 1 min to following portions after which measurement shall be made: (1) Between body and conductor (2) Between conductors not to be contact (3) Between conductors not to be when plug is inserted. | Performance | 100 M MIN |
| Dielectric Strength | AC 100V (rms, 50~60Hz) for 1 min. Trip current: 0.5mA. (1) Between body and conductor (2) Between conductors not to be contact (3) Between conductors not to be when plug is inserted. | Performance | Without damage to parts, arcing or breakdown etc. |
| Solderability Test | The top of the terminals shall be dipped 1mm in the solder bath of 2505 for 50.5 seconds. | Performance | (1) Solder wetting time shall be 3 sec or less. (2) The area of soldering should be over 75%. |
| Resistance to Soldering Heat Test | Reflow soldering conditions: Preheat: Temperature on the copper foil surface should reach 180, 120s after the P.C.B entered into the soldering equipment. Tallest temperature: Temperature on the copper foil surface should reach the peak temperature of 2605 within 20 seconds. | Performance | Without deformation of case or excessive looseness of terminals. Electrical characteristics shall be satisfied. |
| Soldering iron method: Bit temperature 3305 Application time of soldering iron 30.5 sec. However, excessive pressure shall not be applied to the terminal. | Performance | Without deformation of case or excessive looseness of terminals. Electrical characteristics shall be satisfied. | |
| Humidity Test | The jack shall be stored at a temperature of 402 and a humidity of 90% to 96% for 96 Hr, then the jack shall be maintained at standard atmospheric condition for 1 Hr for other procedures. | Performance | There shall be no damage on appearance. Mechanical and electrical characteristics shall be satisfied. |
| Heat Test | The jack shall be stored at a temperature of 702 for 96 hours, and then it shall be subjected to the controlled recovery measurement. | Performance | There shall be no damage on appearance. Mechanical and electrical characteristics shall be satisfied. |
| Cold Test | The jack shall be stored at a temperature of -253 for 96 hours and then it shall be subjected to the controlled recovery conditions for 1 hour after which. | Performance | There shall be no damage on appearance. Mechanical and electrical characteristics shall be satisfied. |
| Life Test | Without load. Connection and disconnection shall be made with the mating plugs and jacks for 3000 cycles at a speed of 10 to 25 cycles/min. | Performance | (1) Contact resistance shall be 0.1. (2) Disconnection force shall be 0.8 to 2.0N. (3) Other: Mechanical and electrical characteristics shall be satisfied. |
| Load: At rating condition (non-inductive load). Connection and disconnection shall be made 3000 cycles at a speed 10 to 20 cycles/min. | Performance | (1) Contact resistance shall be 0.1. (2) Disconnection force shall be 0.8 to 2.0N. (3) Other: Mechanical and electrical characteristics shall be satisfied. | |
| Temperature Cycling Test | The jack shall be subjected to 5 cycles of the following conditions, and then shall be returned and allowed to remain in room ambient condition for 30 minutes. | Performance | Product shall not be deformed or cracked. Insertion & Extraction Force: 3 to 20N. Contact Resistance: Max. 30m. Insulation Resistance: Min. 100 M. Dielectric Withstanding Voltage: 100VAC/min (between terminals). |
| Cold & Heat Shock Test | The jack shall be subjected to 5 cycles of the following conditions, and then shall be returned and allowed to remain in room ambient condition for 30 minutes. | Performance | Product shall not be deformed or cracked. Insertion & Extraction Force: 3 to 25N. Contact Resistance: Max. 30m. Insulation Resistance: Min. 100 M. Dielectric Withstanding Voltage: 500VAC/min (between terminals). |
|
|
SHOU HAN TYPE-C 6P Images |