| Sign In | Join Free | My benadorassociates.com |
|
Delivery Time : 5-6周
Packaging Details : Through Hole
Voltage Rating : 30V
Current Rating : 3A
Description : USB-C (USB TYPE-C) Receptacle Connector 24 Position Surface Mount, Right Angle
Connector Type : Type-C
Model Number : USB-306F
Gender : Female
MOQ : 1000
Mounting Type : Surface Mount, Right Angle
Operating Temperature : -20℃~+60℃
Number of Ports : 1
Stock : 10000
Brand Name : USB-306F
Number of Contacts : 24P
This document outlines the specifications for a USB connector, detailing its electrical and environmental performance characteristics. It is designed for applications requiring reliable data transfer and power delivery.
| Item | Description | Test Methods | Test Specification |
|---|---|---|---|
| 7-1 | Insulation Resistance Unmated | EIA 364-21C | 100M minimum (unmated) between adjacent contacts and contacts and shell ground. Apply 100 Volts DC. |
| 7-2 | Low Level Contact Resistance | EIA 364-23b | 40m(Max) initial for VBUS and GND contacts and all other contacts; delta 10m(Max) after test. 20mV Max. open circuit at 100mA Max. |
| 7-3 | Dielectric Withstanding Voltage | EIA 364-20 | There shall be no breakdown. Subjected to 100VAC (RMS) for 1 minute between adjacent terminals. |
| 7-4 | Contact Current Rating | EIA364-70 | 5.0A collectively to VBUS pins, 1.25A to VCONN pin, and 0.25A to other contacts. Temperature rise shall not exceed 30 C at an ambient temperature of 25 C. |
| 8-1 | Temperature Life | EIA 364-17 | 105C without applied voltage for 120 hours. 105C without applied voltage for 72 hours (preconditioning). Visual inspection, test sequences defined in EIA 364-1000.01. |
| 8-2 | Thermal Shock | EIA 364-32 | 10 Cycles -55C and +85C. USB 3.0 connectors must be mated. No physical damage. |
| 8-3 | Salt Spray | MIL-STD-202F, Method 101D, Test Condition B | 48 hours at 35C with 5% Salt-solution concentration. Shall meet visual requirement, no physical damage. Shall meet requirements of additional tests as specified in test sequence in Section 5. |
| Cycle Test | Durability | EIA 364-09 | Type C: 10000 cycles. Must meet: Contact resistance (40m > delta 10m Max), Insertion force (5N to 20N), Extraction force (8N to 20N), Visual inspection (no exposed base metal). |
| Cable Flexing | Cable Flexing | EIA 364-41 | 100 cycles in 2 planes at 120 degrees. Dimension x=3.7x cable diameter. No discontinuity over 1 microsecond. No physical damage. |
| Cable Pull-Out | Cable Pull-Out | EIA-364-38 | 40N steady state axial load for 1 minute. No discontinuity or physical damage. |
| 4-axes continuity test | 4-axes continuity test | EIA364-18 | 8N tensile force for 10 seconds. Subject to 0, 90, 180, 270 direction. No discontinuity greater than 1s and no physical damage. |
|
|
HOOYA USB-306F Images |